Running watts and the spike
Generator sizing calculator
Check the loads you would run at the same time, then replace the watts with the labels on your own appliances. The total is a shopping range for an electrician, not a permit.
Reviewed November 26, 2026
The method, in one paragraph
Add the running watts of everything you checked. Find the motor with the biggest gap between starting watts and running watts. The peak is the running total, minus that motor’s running watts, plus its starting watts. A 20 percent cushion on the running total is a planning margin so the machine is not pinned at full load. It is not a requirement from the electrical code. A permitted standby generator is sized by a licensed electrician under the National Electrical Code rules for optional standby systems, which are stricter and more specific than this worksheet.
Never backfeed a house by plugging a generator into a dryer outlet. That can energize the line your neighbor’s lineman is holding. A transfer switch or a mechanical interlock, installed under a permit, is how a portable connects to a panel. Extension cords go to appliances, they are rated for the load, and they stay out of standing water.
Running watts are modest. The compressor start is the spike.
Skip if you do not have one.
A handful of bulbs, not every fixture in the house.
The modem still needs the internet cabinet to have power.
Read the power supply. A heated humidifier uses more.
Often more realistic than central air after a storm.
Use the label. A 10,000 BTU unit is often near this range.
The real number is on the condenser nameplate (RLA and LRA). This default is only a placeholder so the total is not quietly small.
If you have one, it is not optional during rain.
No municipal water and no pump means no toilets. Check the horsepower.
You will not run this with the AC compressor starting.
A short load. Uncheck it if you only care about the overnight total.
A spike of a few seconds. The door can also be opened by hand if you know how.
Laundry can wait. Included so the number is available.
Usually a poor use of a portable generator.
A large continuous load. Most portable generators should not be asked to carry it.
Planning total
Check the loads you need at the same time.
How to read the nameplate
Portable generators are sold on running watts and a higher starting number. Match your running total to the running rating, and your peak to the starting rating. A 5,000-watt “peak” machine that runs at 3,800 watts does not carry a 4,500-watt water heater.
For central air, the condenser label lists RLA (running load amps) and LRA (locked rotor amps). Multiply amps by volts to get a rough wattage, then hand the photo to an electrician. A soft-start kit can cut the spike. It does not change the fact that a three-ton system is a large machine. The placeholder in the calculator, 3,500 running and 9,000 starting, exists so the total is not accidentally small. It is not your unit.
Fuel: read the manual for gallons per hour at the load you will actually use. This page will not invent a burn rate. Many Treasure Coast streets do not have natural gas. Fort Pierce Utilities Authority sells gas in its territory. Everywhere else, ask the utility before anyone prices a natural-gas standby unit. Propane means a tank, a setback, and sometimes an association approval. Gasoline for a portable does not belong in a condo, and it goes stale. The owner’s manual says how to store it.
An inverter generator is the usual portable when the list is a refrigerator, fans, chargers, and a medical device. It is quieter and cleaner power for electronics. It is still a carbon monoxide source. Whole-home standby pricing is on the generator cost page.
Questions worth asking
Why is the peak so much higher than the running total?
Motors, especially the refrigerator and the air conditioner, draw a short spike when they start. The calculator applies the single biggest spike on top of the other running loads. It does not assume every motor starts at the same instant.
Can I run this on my balcony if I point the exhaust outward?
No. Exhaust pools and blows back into sliders. Associations on the Treasure Coast commonly forbid portable generators on balconies, and carbon monoxide deaths happen in exactly this setup. Use a battery bank and a place to go.
Does a bigger generator need a permit in Port St. Lucie?
A permanent generator and the electrical work to connect one need a permit from the building department that covers your address. A portable used with extension cords is still illegal to connect by backfeeding. Ask the city or county before you pour a pad.
Sources
Checked November 26, 2026. Pages move. If a county site and this guide disagree while a storm is in the basin, use the county site.